Skip to content
ARRAA Labs

NABL & CDSCO Accredited Testing Lab

  • Home
  • About Us
  • EMI EMC
    arraalabs emi emc test
    • Electrostatic Discharge (ESD)
    • Electrical Fast Transient (EFT)
    • Surge / Telecom Surge Test
    • AC / DC Dips & Ripple Test
    • Magnetic Field Test 
    • Power Frequency Magnetic Field Test
    • Harmonics & Flicker Current Emission Test
    • Damped & Ring Waves Test
    • Conducted Disturbances RF Test
    • Common Mode Disturbances Test
  • Durability
    arraalabs durability test
    • Vibration Test
    • Shock & Bump
    • Seismic Test
  • Environmental
    arraalabs environmental test
    • Dry Heat Test
    • Cold Test
    • Damp Heat, Steady State Test
    • Damp Heat, Cyclic Test
    • Change of Temperature Test
  • Industries
    the best product testing lab in chennai

    Medical

    automotive products testing lab in chennai

    Automotive

    power drive products testing lab in chennai

    Power Drive

    UPS service chennai

    UPS

    lift electrical service chennai

    Lift

    power protection services in chennai

    Relays

    energy meter testing lab chennai

    Measurement

    railway electrical protection services chennai

    Railways

    telecommunication services chennai

    Telecommunication

  • Gallery
  • Blog
  • Contact Us
+91 99945 41008

Electronics Environmental Testing Certification With IEC Standard

SL. NoDiscipline / GroupMaterials or Products testedType of tests performedType of Test standardRange of testing/
Limit of detection
Measurement Uncertainty (+- )
1Electronics-Environmental Test FacilityElectrical, Electronic and Electro-mechanical Items, Metering, relays, Maritime navigation and radiocommunication, Rolling stock (Railway), Electrical Power Drive, Telecommunications Equipment’s. Audio/video, information, and communication technology equipmentDry Heat TestIEC-60068-2-2:2007Temperature (°C)
30 to 175°C
NA
2Electronics-Environmental Test FacilityElectrical, Electronic and Electro-mechanical Items, Metering, relays, Maritime navigation and radiocommunication, Rolling stock (Railway), Electrical Power Drive, Telecommunications Equipment’s. Audio/video, information, and communication technology equipmentCold TestIEC-60068-2-2:2007Temperature (°C)
-40, -to +5°C

NA
3Electronics-Environmental Test FacilityElectrical, Electronic and Electro-mechanical Items, Metering, relays, Maritime navigation and radiocommunication, Rolling stock (Railway), Electrical Power Drive, Telecommunications Equipment’s. Audio/video, information, and communication technology equipmentDamp Heat, Steady State TestIEC-60068-2-78:2012Temperature (°C)
30±2 & 40±2 °C

Relative Humidity (%RH)
85±3 to 93±3 %
NA
4Electronics-Environmental Test FacilityElectrical, Electronic and Electro-mechanical Items, Metering, relays, Maritime navigation and radiocommunication, Rolling stock (Railway), Electrical Power Drive, Telecommunications Equipment’s. Audio/video, information, and communication technology equipmentDamp Heat, Cyclic TestIEC-60068-2-30:2005Temperature(°C)
40°C & 55°C
RH: 93±3%
Ramp : 1°C/min
NA
5Electronics-Environmental Test FacilityElectrical, Electronic and Electro-mechanical Items, Metering, relays, Maritime navigation and radiocommunication, Rolling stock (Railway), Electrical Power Drive, Telecommunications Equipment’s. Audio/video, information, and communication technology equipmentChange of Temperature TestIEC-60068-2-14:2023Temperature (°C):
-40 to 175°C

Ramp – 1°C/min
NA
6Electronics-Environmental Test FacilityElectrical, Electronic and Electro-mechanical Items, Metering, relays, Maritime navigation and radiocommunication, Rolling stock (Railway), Electrical Power Drive, Telecommunications Equipment’s. Audio/video, information, and communication technology equipmentVibration (Sinusoidal) TestIEC 60068-2-6:2007Force:2000kgf Frequency (Hz)
1 to 2000Hz and 3000 Hz
Acceleration:500m/s2
NA
7Electronics-Environmental Test FacilityElectrical, Electronic and Electro-mechanical Items, Metering, relays, Maritime navigation and radiocommunication, Rolling stock (Railway), Electrical Power Drive, Telecommunications Equipment’s. Audio/video, information, and communication technology equipmentVibration,
broad band
random
IEC 60068-2-64: 2008+AMD1:2019Force:2000kgf Frequency (Hz)NA
8Electronics-Environmental Test FacilityElectrical, Electronic and Electro-mechanical Items, Metering, relays, Maritime navigation and radiocommunication, Rolling stock (Railway), Electrical Power Drive, Telecommunications Equipment’s. Audio/video, information, and communication technology equipmentShock TestIEC 60068-2-27:2008Acceleration(g) – 5 to 30g and 80g
Duration(ms) – 6, 11, 16, 18, 30
NA
9Electronics-Environmental Test FacilityElectrical, Electronic and Electro-mechanical Items, Metering, relays, Maritime navigation and radiocommunication, Rolling stock (Railway), Electrical Power Drive, Telecommunications Equipment’s. Audio/video, information, and communication technology equipmentSeismic TestIEC 60068-3-3:2019Peak displacement – 0.1m
Peak velocity – 0.05m/s
Peak acceleration – 5m/s^2
Frequency 1Hz-35Hz
NA
10Electronics-Environmental Test FacilityElectricity Metering EquipmentDry Heat TestIEC 62052-11,2020Temperature :68 °C to 72°CNA
11Electronics-Environmental Test FacilityElectricity Metering EquipmentCold TestIEC 62052-11,2020Temperature:
-22 °C to -43°C
NA
12Electronics-Environmental Test FacilityElectricity Metering EquipmentDamp Heat Cyclic TestIEC 62052-11,2020Temperature:
40±2 to 55±2°C
Ramp – 1°C/min
NA
13Electronics-Environmental Test FacilityElectricity Metering EquipmentVibration (Sinusoidal) TestIEC 62052-11,2020Frequency – 10-150 Hz
No of Sweep per axis – 10
NA
14Electronics-Environmental Test FacilityElectricity Metering EquipmentShock TestIEC 62052-11,2020Acceleration – 30g
Duration of pulse – 18ms
NA
15Electronics-Environmental Test FacilityMeasuring relays and protection equipmentDry Heat TestIEC 60255-1,2022Temperature: 30 to 175°CNA
16Electronics-Environmental Test FacilityMeasuring relays and protection equipmentDamp Heat, Steady State TestIEC 60255-1,2022Temperature:
40±2 °C
Humidity :93±3%
NA
17Electronics-Environmental Test FacilityMeasuring relays and protection equipmentCold TestIEC 60255-1,2022Temperature: -40, -to +5°C
Duration – 96h
NA
18Electronics-Environmental Test FacilityMeasuring relays and protection equipmentDamp Heat, Cyclic TestIEC 60255-1,2022Low Temperature: 25±3 °C @ 97+3/-2% of RH
Upper Temperature: 40±2 &55±2 °C@ 93±3% of RH
Ramp – 1°C/min
NA
19Electronics-Environmental Test FacilityMeasuring relays and protection equipmentChange of Temperature TestIEC 60255-1,2022Up to -40 to 175°C

Ramp – 1°C±0.2°C /min
NA
20Electronics-Environmental Test FacilityMeasuring relays and protection equipmentVibration (Sinusoidal) Test IEC 60255-21-1:1998Acceleration – 2g
Frequency – 10-150Hz
No of Sweep - 20
NA
21Electronics-Environmental Test FacilityMeasuring relays and protection equipmentShock Test

IEC 60255-21-2:1988Acceleration – 30g
Duration – 11ms
No of pulses - 6
NA
22Electronics-Environmental Test FacilityMeasuring relays and protection equipmentBump TestIEC 60255-21-2:1998Acceleration – 20g
Duration – 16ms
No of pulses - 2000
NA
23Electronics-Environmental Test FacilityMeasuring relays and protection equipmentSeismic TestIEC 60255-21-3:1993Acceleration-2g
Displacement – 7.5mm
No of sweep – 1 each axis
Frequency 1Hz-35Hz

24Electronics-Environmental Test FacilityMaritime navigation and radiocommunication equipment and systemsDry Heat TestIEC 60945:2002Temperature: 67 to73 °CNA
25Electronics-Environmental Test FacilityMaritime navigation and radiocommunication equipment and systemsLow Temperature TestIEC 60945:2002Temperature :-27 to 33 °CNA
26Electronics-Environmental Test FacilityMaritime navigation and radiocommunication equipment and systemsDamp Heat, Cyclic TestIEC 60945:2002Temperature:
40±2 °C
Humidity :93±3%
NA
27Electronics-Environmental Test FacilityMaritime navigation and radiocommunication equipment and systemsVibration (Sinusoidal) TestIEC 60945:2002Frequency – 100 Hz
Acceleration – 7 m/s2
Sweep – 0.5 octaves/min
NA
28Electronics-Environmental Test FacilityAudio/video, information, and communication technology equipmentVibration (Sinusoidal) TestIEC 62368-1 :2018Frequency – 55Hz
Sweep – 1oct/min
NA
29Electronics-Environmental Test FacilityAudio/video, information, and communication technology equipmentDamp Heat, Steady State TestIEC 62368-1 :2018Temperature:
40±2°C
Humidity: 93±3%
NA
30Electronics-Environmental Test FacilityTelecommunications equipmentDry Heat TestETSI EN 300 019-2-2 V2.4.1 (2017-11)Temperature: +70/+85 °CNA
31Electronics-Environmental Test FacilityTelecommunications equipmentCold TestETSI EN 300 019-2-2 V2.4.1 (2017-11)Temperature:
-40 (°C)
NA
32Electronics-Environmental Test FacilityTelecommunications equipmentDamp Heat, Steady State TestETSI EN 300 019-2-2 V2.4.1 (2017-11)Temperature :40°C Humidity :93%NA
33Electronics-Environmental Test FacilityTelecommunications equipmentDamp Heat, Cyclic TestETSI EN 300 019-2-2 V2.4.1 (2017-11)Temperature :40°C
Humidity :90 to100%
NA
34Electronics-Environmental Test FacilityTelecommunications equipmentChange of Temperature TestETSI EN 300 019-2-2 V2.4.1 (2017-11)Temperature:
-40/+30°C
Rate of change – 1 deg/min
Cycles - 5
NA
35Electronics-Environmental Test FacilityTelecommunications equipmentVibration,
broad band
random
ETSI EN 300 019-2-2 V2.4.1 (2017-11)Frequency: up to 200Hz
Acceleration:1m/s2
NA
36Electronics-Environmental Test FacilityElectrical Power DriveDry Heat TestBS EN 61800-5-1:2021Temperature: 40 °C or specified tempNA
37Electronics-Environmental Test FacilityElectrical Power DriveDamp Heat, Steady State TestBS EN 61800-5-1:2021Temperature :40±2 °C
Humidity :93(+2/- 3 )%

NA
38Electronics-Environmental Test FacilityElectrical Power DriveVibration (Sinusoidal) TestBS EN 61800-5-1:2021Humidity :93(+2/- 3 )%NA
39Electronics-Environmental Test FacilitySafety of MachineryVibration (Sinusoidal) TestIEC 61496-1:2020Frequency – 5 to 500Hz
Acceleration – 5g
Acceleration Spectral density – 5 m2/s3
NA
40Electronics-Environmental Test FacilitySafety of MachineryShock TestIEC 61496-1:2020Acceleration – 30g
Duration – 11ms
NA
41Electronics-Environmental Test FacilityRailway applications – Electronic equipment used on rolling stockDry Heat TestIEC 61373:2010Temperature (°C)
-40°C to +5°C
NA
42Electronics-Environmental Test FacilityRailway applications – Electronic equipment used on rolling stockDamp Heat, Cyclic TestIEC 61373:2010Temperature (°C)
30 to 175°C
NA
43Electronics-Environmental Test FacilityRailway applications – Electronic equipment used on rolling stockVibration,
broad band
random
IEC 61373:2010Temperature(°C)
40°C & 55°C
RH: 93±3%
Ramp: 1°C/min
NA
44Electronics-Environmental Test FacilityRailway applications – Electronic equipment used on rolling stockShockIEC 61373:2010Frequency:500Hz
Acceleration:64.3 m/s2

NA
45Electronics-Environmental Test FacilityRailway applications – Electronic equipment used on rolling stockElectrostatic Discharge Immunity test (ESD)IEC 61373:2010Acceleration:300 m/s2
Pulse width:30 ms
NA
PrevPreviousElectronics EMC Testing Certification With IEC Standard
NextARRAA Labs GalleryNext

ABOUT ARRAA LABS

ARRAA Labs, an EMI/EMC, Environmental, and Vibration Testing company, is an independent NABL testing laboratory that performs inspection, certification, and testing for all kinds of industries that manufacture mechanical, electrical, and electronic products.

Facebook Whatsapp Linkedin Instagram Twitter X Logo

Quick Links

  • EMI EMC
  • Durability
  • Environmental
  • Industries
  • Blog
  • Career
  • Contact
  • +91 99945 41008
  • +91 90433 23091
  • enquiry@arraalabs.com
ARRAA Labs © Copyright 2024. All right reserved.
  • Terms & Conditions
  • Privacy Policy
Developed By Dextra Technologies
  • FaceBook
  • WhatsApp
  • Linkedin
  • Instagram
Scroll Up