Skip to content
ARRAA Labs

NABL & CDSCO Accredited Testing Lab

  • Home
  • About Us
  • EMI EMC
    arraalabs emi emc test
    • Electrostatic Discharge (ESD)
    • Electrical Fast Transient (EFT)
    • Surge / Telecom Surge Test
    • AC / DC Dips & Ripple Test
    • Magnetic Field Test 
    • Voltage Dips, Short Interruptions Immunity Test
    • Power Frequency Magnetic Field Test
    • Harmonics & Flicker Current Emission Test
    • Damped & Ring Waves Test
    • Conducted Disturbances RF Test
    • Common Mode Disturbances Test
  • Durability
    arraalabs durability test
    • Vibration Test
    • Shock & Bump
    • Seismic Test
  • Environmental
    arraalabs environmental test
    • Dry Heat Test
    • Cold Test
    • Damp Heat, Steady State Test
    • Damp Heat, Cyclic Test
    • Change of Temperature Test
  • Calibration
    • Electro-Technical
      • EMI EMC Calibration
      • (AC) Calibration
      • (DC) Calibration
    • Thermal Calibration
  • Industries
    the best product testing lab in chennai

    Medical

    automotive products testing lab in chennai

    Automotive

    power drive products testing lab in chennai

    Power Drive

    UPS service chennai

    UPS

    lift electrical service chennai

    Lift

    power protection services in chennai

    Relays

    energy meter testing lab chennai

    Measurement

    railway electrical protection services chennai

    Railways

    telecommunication services chennai

    Telecommunication

  • Gallery
  • Blog
  • Certificate
  • Contact Us
+91 99945 41008

Electrical Fast Transient Generator Calibration

At ARRAA Labs, we specialize in Electrical Fast Transient (EFT) Generator Calibration and Testing Services with precision measurement capabilities and NABL-compliant procedures. Our expert calibration services ensure the accuracy, reliability, and compliance of EFT generators used for EMI/EMC testing across electrical, electronics, automotive, industrial, and research applications.

Our EFT Generator Calibration Measurement Capabilities include precise calibration of rise time measurements from 5 ns to 5.5 ns, ensuring accurate transient pulse characterization. We offer pulse duration calibration for 0.75 ms, 15 ms, and 300 ms waveforms, along with output voltage calibration ranges from (±)100 V to (±)2.75 kV and (±)200 V to (±)5.5 kV. Our services also cover repetition frequency calibration from 1 kHz to 1 MHz, helping manufacturers, testing laboratories, and EMC professionals maintain compliance with international standards and achieve reliable, repeatable test results.

Discipline / GroupMeasurand or Reference
Material
Calibration or Measurement
Method or procedure
Measurement range and
additional parameters
where applicable(Range
and Frequency
* Calibration and
Measurement
Capability(CMC)(±)
ELECTRO- TECHNICAL-
EMI/ EMC (Measure)
Electrical fast transient Test System: Generator / CDN EUT-output:
Pulse Rise Time
Using Digital Storage Oscilloscope with Load Resistor 50 ohm / 1000 ohm by Direct Method as per IEC 61000- 4-4:20125.5 ns7.05 %
ELECTRO- TECHNICAL-
EMI/ EMC (Measure)
Electrical fast transient Test System: Generator / CDN EUT-output: Pulse Rise TimeUsing Digital Storage Oscilloscope with Load Resistor 50 ohm / 1000 ohm by Direct Method as per IEC 61000- 4-4:20125 ns7.86 %
ELECTRO- TECHNICAL-
EMI/ EMC (Measure)
Electrical fast transient Test System: Generator
/CDN - EUT Output -Voltage Pulse Width
(Tw)
Using Digital Storage Oscilloscope with Load Resistor 50 ohm /1000 ohm: (45 ± 15) ns by Direct Method as per IEC 61000-4-4:201245 ns9.98 %
ELECTRO- TECHNICAL-
EMI/ EMC (Measure)
Electrical fast transient Test System: Generator
/CDN - EUT Output -Voltage Pulse Width
(Tw)
Using Digital Storage Oscilloscope with Load Resistor 50 and 1000 ohm by Direct Method as per IEC 61000-4- 4:201250 ns8.62 %
ELECTRO- TECHNICAL-
EMI/ EMC (Measure)
Electrical fast transient Test System: Generator / CDN / Clamp Output
- Burst Duration @ 5 kHz
Using Digital Storage Oscilloscope with Load Resistor 50 ohm & 1000 ohm by Direct Method as per IEC 61000-4-4:2012: @ 15 ± 3 ms15 ms8.18 %
ELECTRO- TECHNICAL-
EMI/ EMC (Measure)
Electrical fast transient Test System: Generator / CDN / Clamp Output
- Burst Duration @ 100 kHz
Using Digital Storage Oscilloscope with Load Resistor 50 ohm & 1000 ohm by Direct Method as per IEC 61000-4-4:2012 @ 0.75 ± 0.15 ms0.75 ms8.35 %
ELECTRO- TECHNICAL-
EMI/ EMC (Measure)
Electrical fast transient Test System: Generator / CDN / Clamp Output
- Repetition Frequency
Using Digital Storage Oscilloscope with Load Resistor 50ohm & 1000 ohm by Direct Method as per IEC 61000-4-4:2012 (± 20 %)1 kHz to 1 MHz8.03 % to 7.91 %
ELECTRO- TECHNICAL-
EMI/ EMC (Measure)
Electrical fast transient Test System: Generator / CDN / Clamp Output
- Burst Period
Using Digital Storage Oscilloscope with Load Resistor 50 ohm & 1000 ohm by Direct Method as per IEC 61000-4-4:2012 (± 60 ms)300 ms8.27 %
ELECTRO- TECHNICAL-
EMI/ EMC (Measure)
Electrical fast transient Test System: Generator / CDN / Clamp Output
- Pulse Amplitude
Using Digital Storage Oscilloscope with Load Resistor 50ohm (±10%) by Direct Method as per
IEC 61000- 4-4:2012
(±) 100 V to (±)
2.75 kV
8.25 % to 8.12 %
ELECTRO- TECHNICAL-
EMI/ EMC (Measure)
Electrical fast transient Test System: Generator / CDN / Clamp Output
- Pulse Amplitude
Using Digital Storage Oscilloscope with Load Resistor 1000 ohm (± 20 %) by Direct Method as
per IEC 61000-4-4:2012
(±) 200 V to (±) 5.5
kV
8.36 % to 7.48 %

Our Electrical Fast Transient (EFT) Generator Calibration Services help manufacturers, testing laboratories, R&D centers, and quality assurance teams maintain compliance with international EMC standards and ensure accurate test results.

Our state-of-the-art calibration laboratory is located in Chennai, India, and we provide Electrical Fast Transient (EFT) Generator Calibration Services across India, delivering accurate, traceable, and industry-compliant calibration solutions to customers in the electronics, electrical, automotive, industrial, and research sectors.

PrevPreviousElectro Technical EMI EMC Calibration Testing
NextHarmonics and Flicker Generator CalibrationNext

ABOUT ARRAA LABS

ARRAA Labs, an EMI/EMC, Environmental, and Vibration Testing company, is an independent NABL testing laboratory that performs inspection, certification, and testing for all kinds of industries that manufacture mechanical, electrical, and electronic products.

Facebook Whatsapp Linkedin Instagram Twitter X Logo

Quick Links

  • EMI EMC
  • Durability
  • Environmental
  • Industries
  • Blog
  • Career
  • Contact
  • +91 99945 41008
  • +91 90433 23091
  • enquiry@arraalabs.com
ARRAA Labs © Copyright 2024. All right reserved.
  • Terms & Conditions
  • Privacy Policy
Developed By Dextra Technologies
  • WhatsApp
Scroll Up