| SL. No | Discipline / Group | Materials or Products tested | Type of tests performed | Type of Test standard | Range of testing/ Limit of detection | Measurement Uncertainty (+- ) |
|---|---|---|---|---|---|---|
| 1 | Electronics-Environmental Test Facility | Electrical, Electronic and Electro-mechanical Items, Metering, relays, Maritime navigation and radiocommunication, Rolling stock (Railway), Electrical Power Drive, Telecommunications Equipment’s. Audio/video, information, and communication technology equipment | Dry Heat Test | IEC-60068-2-2:2007 | Temperature (°C) 30 to 175°C | NA |
| 2 | Electronics-Environmental Test Facility | Electrical, Electronic and Electro-mechanical Items, Metering, relays, Maritime navigation and radiocommunication, Rolling stock (Railway), Electrical Power Drive, Telecommunications Equipment’s. Audio/video, information, and communication technology equipment | Cold Test | IEC-60068-2-2:2007 | Temperature (°C) -40, -to +5°C | NA |
| 3 | Electronics-Environmental Test Facility | Electrical, Electronic and Electro-mechanical Items, Metering, relays, Maritime navigation and radiocommunication, Rolling stock (Railway), Electrical Power Drive, Telecommunications Equipment’s. Audio/video, information, and communication technology equipment | Damp Heat, Steady State Test | IEC-60068-2-78:2012 | Temperature (°C) 30±2 & 40±2 °C Relative Humidity (%RH) 85±3 to 93±3 % | NA |
| 4 | Electronics-Environmental Test Facility | Electrical, Electronic and Electro-mechanical Items, Metering, relays, Maritime navigation and radiocommunication, Rolling stock (Railway), Electrical Power Drive, Telecommunications Equipment’s. Audio/video, information, and communication technology equipment | Damp Heat, Cyclic Test | IEC-60068-2-30:2005 | Temperature(°C) 40°C & 55°C RH: 93±3% Ramp : 1°C/min | NA |
| 5 | Electronics-Environmental Test Facility | Electrical, Electronic and Electro-mechanical Items, Metering, relays, Maritime navigation and radiocommunication, Rolling stock (Railway), Electrical Power Drive, Telecommunications Equipment’s. Audio/video, information, and communication technology equipment | Change of Temperature Test | IEC-60068-2-14:2023 | Temperature (°C): -40 to 175°C Ramp – 1°C/min | NA |
| 6 | Electronics-Environmental Test Facility | Electrical, Electronic and Electro-mechanical Items, Metering, relays, Maritime navigation and radiocommunication, Rolling stock (Railway), Electrical Power Drive, Telecommunications Equipment’s. Audio/video, information, and communication technology equipment | Vibration (Sinusoidal) Test | IEC 60068-2-6:2007 | Force:2000kgf Frequency (Hz) 1 to 2000Hz and 3000 Hz Acceleration:500m/s2 | NA |
| 7 | Electronics-Environmental Test Facility | Electrical, Electronic and Electro-mechanical Items, Metering, relays, Maritime navigation and radiocommunication, Rolling stock (Railway), Electrical Power Drive, Telecommunications Equipment’s. Audio/video, information, and communication technology equipment | Vibration, broad band random | IEC 60068-2-64: 2008+AMD1:2019 | Force:2000kgf Frequency (Hz) | NA |
| 8 | Electronics-Environmental Test Facility | Electrical, Electronic and Electro-mechanical Items, Metering, relays, Maritime navigation and radiocommunication, Rolling stock (Railway), Electrical Power Drive, Telecommunications Equipment’s. Audio/video, information, and communication technology equipment | Shock Test | IEC 60068-2-27:2008 | Acceleration(g) – 5 to 30g and 80g Duration(ms) – 6, 11, 16, 18, 30 | NA |
| 9 | Electronics-Environmental Test Facility | Electrical, Electronic and Electro-mechanical Items, Metering, relays, Maritime navigation and radiocommunication, Rolling stock (Railway), Electrical Power Drive, Telecommunications Equipment’s. Audio/video, information, and communication technology equipment | Seismic Test | IEC 60068-3-3:2019 | Peak displacement – 0.1m Peak velocity – 0.05m/s Peak acceleration – 5m/s^2 Frequency 1Hz-35Hz | NA |
| 10 | Electronics-Environmental Test Facility | Electricity Metering Equipment | Dry Heat Test | IEC 62052-11,2020 | Temperature :68 °C to 72°C | NA |
| 11 | Electronics-Environmental Test Facility | Electricity Metering Equipment | Cold Test | IEC 62052-11,2020 | Temperature: -22 °C to -43°C | NA |
| 12 | Electronics-Environmental Test Facility | Electricity Metering Equipment | Damp Heat Cyclic Test | IEC 62052-11,2020 | Temperature: 40±2 to 55±2°C Ramp – 1°C/min | NA |
| 13 | Electronics-Environmental Test Facility | Electricity Metering Equipment | Vibration (Sinusoidal) Test | IEC 62052-11,2020 | Frequency – 10-150 Hz No of Sweep per axis – 10 | NA |
| 14 | Electronics-Environmental Test Facility | Electricity Metering Equipment | Shock Test | IEC 62052-11,2020 | Acceleration – 30g Duration of pulse – 18ms | NA |
| 15 | Electronics-Environmental Test Facility | Measuring relays and protection equipment | Dry Heat Test | IEC 60255-1,2022 | Temperature: 30 to 175°C | NA |
| 16 | Electronics-Environmental Test Facility | Measuring relays and protection equipment | Damp Heat, Steady State Test | IEC 60255-1,2022 | Temperature: 40±2 °C Humidity :93±3% | NA |
| 17 | Electronics-Environmental Test Facility | Measuring relays and protection equipment | Cold Test | IEC 60255-1,2022 | Temperature: -40, -to +5°C Duration – 96h | NA |
| 18 | Electronics-Environmental Test Facility | Measuring relays and protection equipment | Damp Heat, Cyclic Test | IEC 60255-1,2022 | Low Temperature: 25±3 °C @ 97+3/-2% of RH Upper Temperature: 40±2 &55±2 °C@ 93±3% of RH Ramp – 1°C/min | NA |
| 19 | Electronics-Environmental Test Facility | Measuring relays and protection equipment | Change of Temperature Test | IEC 60255-1,2022 | Up to -40 to 175°C Ramp – 1°C±0.2°C /min | NA |
| 20 | Electronics-Environmental Test Facility | Measuring relays and protection equipment | Vibration (Sinusoidal) Test | IEC 60255-21-1:1998 | Acceleration – 2g Frequency – 10-150Hz No of Sweep - 20 | NA |
| 21 | Electronics-Environmental Test Facility | Measuring relays and protection equipment | Shock Test | IEC 60255-21-2:1988 | Acceleration – 30g Duration – 11ms No of pulses - 6 | NA |
| 22 | Electronics-Environmental Test Facility | Measuring relays and protection equipment | Bump Test | IEC 60255-21-2:1998 | Acceleration – 20g Duration – 16ms No of pulses - 2000 | NA |
| 23 | Electronics-Environmental Test Facility | Measuring relays and protection equipment | Seismic Test | IEC 60255-21-3:1993 | Acceleration-2g Displacement – 7.5mm No of sweep – 1 each axis Frequency 1Hz-35Hz | |
| 24 | Electronics-Environmental Test Facility | Maritime navigation and radiocommunication equipment and systems | Dry Heat Test | IEC 60945:2002 | Temperature: 67 to73 °C | NA |
| 25 | Electronics-Environmental Test Facility | Maritime navigation and radiocommunication equipment and systems | Low Temperature Test | IEC 60945:2002 | Temperature :-27 to 33 °C | NA |
| 26 | Electronics-Environmental Test Facility | Maritime navigation and radiocommunication equipment and systems | Damp Heat, Cyclic Test | IEC 60945:2002 | Temperature: 40±2 °C Humidity :93±3% | NA |
| 27 | Electronics-Environmental Test Facility | Maritime navigation and radiocommunication equipment and systems | Vibration (Sinusoidal) Test | IEC 60945:2002 | Frequency – 100 Hz Acceleration – 7 m/s2 Sweep – 0.5 octaves/min | NA |
| 28 | Electronics-Environmental Test Facility | Audio/video, information, and communication technology equipment | Vibration (Sinusoidal) Test | IEC 62368-1 :2018 | Frequency – 55Hz Sweep – 1oct/min | NA |
| 29 | Electronics-Environmental Test Facility | Audio/video, information, and communication technology equipment | Damp Heat, Steady State Test | IEC 62368-1 :2018 | Temperature: 40±2°C Humidity: 93±3% | NA |
| 30 | Electronics-Environmental Test Facility | Telecommunications equipment | Dry Heat Test | ETSI EN 300 019-2-2 V2.4.1 (2017-11) | Temperature: +70/+85 °C | NA |
| 31 | Electronics-Environmental Test Facility | Telecommunications equipment | Cold Test | ETSI EN 300 019-2-2 V2.4.1 (2017-11) | Temperature: -40 (°C) | NA |
| 32 | Electronics-Environmental Test Facility | Telecommunications equipment | Damp Heat, Steady State Test | ETSI EN 300 019-2-2 V2.4.1 (2017-11) | Temperature :40°C Humidity :93% | NA |
| 33 | Electronics-Environmental Test Facility | Telecommunications equipment | Damp Heat, Cyclic Test | ETSI EN 300 019-2-2 V2.4.1 (2017-11) | Temperature :40°C Humidity :90 to100% | NA |
| 34 | Electronics-Environmental Test Facility | Telecommunications equipment | Change of Temperature Test | ETSI EN 300 019-2-2 V2.4.1 (2017-11) | Temperature: -40/+30°C Rate of change – 1 deg/min Cycles - 5 | NA |
| 35 | Electronics-Environmental Test Facility | Telecommunications equipment | Vibration, broad band random | ETSI EN 300 019-2-2 V2.4.1 (2017-11) | Frequency: up to 200Hz Acceleration:1m/s2 | NA |
| 36 | Electronics-Environmental Test Facility | Electrical Power Drive | Dry Heat Test | BS EN 61800-5-1:2021 | Temperature: 40 °C or specified temp | NA |
| 37 | Electronics-Environmental Test Facility | Electrical Power Drive | Damp Heat, Steady State Test | BS EN 61800-5-1:2021 | Temperature :40±2 °C Humidity :93(+2/- 3 )% | NA |
| 38 | Electronics-Environmental Test Facility | Electrical Power Drive | Vibration (Sinusoidal) Test | BS EN 61800-5-1:2021 | Humidity :93(+2/- 3 )% | NA |
| 39 | Electronics-Environmental Test Facility | Safety of Machinery | Vibration (Sinusoidal) Test | IEC 61496-1:2020 | Frequency – 5 to 500Hz Acceleration – 5g Acceleration Spectral density – 5 m2/s3 | NA |
| 40 | Electronics-Environmental Test Facility | Safety of Machinery | Shock Test | IEC 61496-1:2020 | Acceleration – 30g Duration – 11ms | NA |
| 41 | Electronics-Environmental Test Facility | Railway applications – Electronic equipment used on rolling stock | Dry Heat Test | IEC 61373:2010 | Temperature (°C) -40°C to +5°C | NA |
| 42 | Electronics-Environmental Test Facility | Railway applications – Electronic equipment used on rolling stock | Damp Heat, Cyclic Test | IEC 61373:2010 | Temperature (°C) 30 to 175°C | NA |
| 43 | Electronics-Environmental Test Facility | Railway applications – Electronic equipment used on rolling stock | Vibration, broad band random | IEC 61373:2010 | Temperature(°C) 40°C & 55°C RH: 93±3% Ramp: 1°C/min | NA |
| 44 | Electronics-Environmental Test Facility | Railway applications – Electronic equipment used on rolling stock | Shock | IEC 61373:2010 | Frequency:500Hz Acceleration:64.3 m/s2 | NA |
| 45 | Electronics-Environmental Test Facility | Railway applications – Electronic equipment used on rolling stock | Electrostatic Discharge Immunity test (ESD) | IEC 61373:2010 | Acceleration:300 m/s2 Pulse width:30 ms | NA |